Sound reduction with double glazed units is an increasing concern for clients and specifiers to improve habitations where noise is a problem, generally in heavily populated areas.
Slimlite Double Glazed Unit cavities are filled with a mixture of Krypton and Xenon inert gases which are much heavier than the standard Argon and therefore provide much better sound reduction than standard units. The widths of cavities has little or no effect on sound reduction. Therfore each cavity will have the same effect.
Sound reduction in standard double glazed units 2 panes of 4mm glass with Air Cavity - 25 Decibels.
Example: Normal noise reduction RW = 31 Decibels - Traffic Ctr = 27 Decibels
Other Constructions - Sound Reduction
Constructed:
Sound is measured over a range of frequencies and sound reduction is shown in Decibels,
and a 3 Decibel reduction in sound will be noticeable.
The higher decibel figure reflects increased sound reduction.
These are the results as tested by the University of Salford (Acounstic Test Laboratory), UKAS ACCREDITED TEST LABORATORY NO. 1262
(click to enlarge)
Slimlite Double Glazed Unit cavities are filled with a mixture of Krypton and Xenon inert gases which are much heavier than the standard Argon and therefore provide much better sound reduction than standard units. The widths of cavities has little or no effect on sound reduction. Therfore each cavity will have the same effect.
Sound reduction in standard double glazed units 2 panes of 4mm glass with Air Cavity - 25 Decibels.
Slimlite Double Glazed Units - Sound Reduction (Acoustic Insulation)
Constructed:Example: Normal noise reduction RW = 31 Decibels - Traffic Ctr = 27 Decibels
| 4mm Low E/4mm Cavity, gas/4mm clear | 31 Decibels | Traffic 27 Decibels | U-Value 1.9 |
| 4mm Low E/5mm Cavity, gas/4mm clear | 31 Decibels | Traffic 27 Decibels | U-Value 1.8 |
| 4mm Low E/6mm Cavity, gas/4mm clear | 31 Decibels | Traffic 27 Decibels | U-Value 1.6 |
| 4mm Low E/8mm Cavity, gas/4mm clear | 31 Decibels | Traffic 27 Decibels | U-Value 1.4 |
Other Constructions - Sound Reduction
Constructed:
| 6mm Low E/4mm Cavity, gas/4mm clear | 33 Decibels | Traffic 30 Decibels | U-Value 1.9 |
| 4mm Low E/4mm Cavity, gas/6.8 Optiphon | 35 Decibels | Traffic 31 Decibels | U-Value 1.9 |
| 4mm Low E/4mm Cavity, gas/10.8 Optiphon | 38 Decibels | Traffic 34 Decibels | U-Value 1.9 |
Sound is measured over a range of frequencies and sound reduction is shown in Decibels,
and a 3 Decibel reduction in sound will be noticeable.
The higher decibel figure reflects increased sound reduction.
These are the results as tested by the University of Salford (Acounstic Test Laboratory), UKAS ACCREDITED TEST LABORATORY NO. 1262(click to enlarge)